CablePiezoBCU0
Known history When Where Who What 20130605 OAA MB Installed in LgswUnitSx in the BlueChannel. 20150618 OAA MB Removed from LgswUnitSx ...
CablePiezoBCU3
Known history When Where Who What 20150604 OAA MB It is on the shelf in the ExIbis lab 20150818 LBT MB Installed on LgswUnitSx in the ...
CablePiezoBCU6
Known history When Where Who What 20130215 OAA Installed in LgswUnitDx in the BlueChannel. Used to connect PiezoS334615 to BcuNumber2 Know is...
CablePiezoBcu
Description Cables used to connect the PI S334 to the BCU. Each piezo head has 5 cables terminated with LEMO connectors: 3 for the HV commands (Axis 1, Axis 2, 10...
DayTime20150630
LGSW FoV center on PatCams 10:00: spots are within the LGSW FoV, we have strong coma: we must flatten the shell. We close the loop on LGSW only and then we save a...
DayTime20150821
Diary 20150820_23xxxx PockelsCell145 installed in BlueChannel replacing PockelsCell144 20150821_150055 PCT measurement 20150821_163526 PCD off ...
DayTime20150823
20150823_170000 LgswUnitSx is powered off. Disconnected from the rack. 20150823_180000 LgswUnitDx is completely disassembled apart for WfsCamera and lenslet...
DayTime20150825
Piezo mirrors alignment Alignment of periscopes. The flange has been remachined at LBT for the new periscope mirrors holders. Gola is to get the beam after the pe...
DayTime20150827
Pockels cells installation A try was done to install insulating foam inside the EM shield boxes. Armaflex foam was provided by MPE in several adhesive sheets. Aft...
DayTime20151019
13:30: we try to calibrate the PatCam to Hexapod movement. We do steps pf 5" around the LGSW FoVs. SX LGSW PatCam to Hexapod IM: 20151019_203311 We determine also...
HowToDefineLgswSubapertures
How to define a subapertures set To create a new subapertures set or just modify the slope computing method you have 2 possibilities: 1 create a new subapertur...
LgswChannels
Rationale In each WFS the 3 laser beams follow indipendent path (or "channels") up to the detector. This means that several devices inside the LgswUnit are instal...
NightTime20151023
17:30: Sx system started from AArb, we try a PockelsCellsTransmission test: TN Plot Map ('20151024_004135','20151024_004258') We start also the ...
Nsa12Number0
Known history When Where Who What 20130320 OAA MB Installed in LgswUnitDx in the BlueChannel Y Know issues When What 20130305 de...
Nsa12Number10
Known history When Where Who What 20130320 OAA MB Installed in LgswUnitDx in the BlueChannel X Know issues When What 20130305 de...
Nsa12Number16
Known history When Where Who What 20130810 OAA MB Received form Newport Know issues When What 20130305 description of issue Cur...
Nsa12Number2
Known history When Where Who What 20130710 OAA MB integrated in LgswUnitSx as PupilMotorBlue Y 20130722 OAA MB To be removed from Lgsw...
r3 - 24 Jan 2014 - 11:20 by TommasoMazzoni
PiezoS334615
Known history When Where Who What 20110413 OAA Delivered from PI Germany with custom mirror from Layertec 20120920 OAA Calibrated us...
PiezoS334620
Known history When Where Who What 20110413 OAA Delivered from PI Germany with custom mirror from Layertec 20130415 OAA Installed in ...
PockelsCell1
Known history When Where Who What 20131108 OAA GOX Shipped to Florence from MPE 20131112 OAA MB, LB Installed on LgswUnitSx BlueChanne...
PockelsCell140
Description This is the new model of PockelsCells rebuild after the OzoneProblem. Known history When Where Who What 20150325 OAA Arrived in Flo...
PockelsCell141
Description This is the new model of PockelsCells rebuild after the OzoneProblem, upgraded to version 2.1 (see PockelsCells) Known history When Where Who ...
PockelsCell142
Description This is the July 2015 model (aka v2.1) of PockelsCells. Known history When Where Who What 201507xx MPE SR Assembled 201508xx ...
PockelsCell144
Description This is the new model of PockelsCells rebuild after the OzoneProblem, upgraded to version 2.1 (see PockelsCells) Known history When Where Who ...
PockelsCell145
Description This is the July 2015 model (aka v2.1) of PockelsCells. Known history When Where Who What 201507xx MPE SR Assembled 201508xx ...
PockelsCell147
Description This is the new model of PockelsCells rebuild after the OzoneProblem, upgraded to version 2.1 (see PockelsCells) Known history When Where Who ...
PockelsCell2
Known history When Where Who What 20130312 OAA SR, JZ Installed in LgswUnitDx in BlueChannel 20131122 OAA MB New shield box and connec...
PockelsCell5
Known history When Where Who What 20130808 OAA Arrived in Florence from MPA 20130912 OAA MB, TM Installed in LgswUnitSx in YellowChann...
PockelsCell6
Known history When Where Who What 20130808 OAA Arrived in Florence from MPE 20130912 OAA MB, TM Installed in LgswUnitSx in BlueChannel...
StepperMotorAdaptorBox
Description Adaptor box is installed inside the LgswUnit. It gets up to 8 motor connected via DB9 connection on the internal side. On the external side it has 2 m...