20140203 |
OAA |
MA |
BCU board HW modified for fastlink issue |
20140204 |
OAA |
LB |
BCU Logic updated to 11.70 |
20140415 |
OAA |
MA, GOX, LB |
Back in OAA after fix the FLAO Input port. BCU logic updated to 11.71 |
20130716 |
OAA |
|
BcuNumber3 received from MPE |
20200925 |
LBT |
GR |
Changed IP address to 192.168.32.140 using the LBTO AO laptop. |
20140415 |
OAA |
MA, GOX, LB |
Communication test using FLAO-ARGOS-SWITCH using BCU_11.71 and 6.08 |
20130730 |
OAA |
MB |
Exchanged with BcuNumber1 in LgswRack2 |
20140415 |
OAA |
MA, GOX, LB |
implemented and tested ADC enable/disable using DSP_8.46 |
20140415 |
OAA |
MA, GOX, LB |
implemented and tested reset to 0 FLAO slopes BCU_11.71 and 6.09 |
20131119 |
OAA |
LB, MA |
Installed BCULogic v11.69 |
20220308 |
LBT |
GR |
Installed in DX LgswRack1. IP address changed to 192.168.31.141 using EngPanel on VirtualBox from dx-lgsw (IP address had been changed while at Microgate). MC comment:" - One DSP board of one of the High Voltage boards. There was probably an aging problem, most likely some soldering spot of the DSP was not very stable. We tried a re-working, which partially succeeded but was not stable, so we decided to replace the whole board
- Some of the relais on the High Voltage board that disconnect the load
All other boards, including the ADC ones, were thoroughly checked and calibrated. |
20161013 |
LBT |
MB |
Installed in LgswRack1 |
20140425 |
LBT |
GR,ML, GOX |
Installed in LgswRack1 for successful ASM communication test |
20200921 |
LBT |
GR |
Installed in SX LgswRack2. IP address still needs to be changed. Issues with EngPanel not working in ARGOS laptop |
201608xx |
MIC |
MA |
Modification on the minicrate power supply to improve the long term stability of the output voltage. With the modification the voltage level on the boards is now very stable and, considering the adopted solution, we assure this stability over long time. (As from MA email of 7/9/2015) |
20141130 |
LBT |
JZ, GOX |
Power supply voltage rised by 50mV from 3.438V to 3.491V |
20160925 |
MPE |
SR |
Received from MicrogateSrl and shipped to LBT |
20220301 |
LBT |
GR |
Received from MicrogateSrl. |
20161005 |
LBT |
GR |
Received from MPE and stored at LBTLevel3L in a gray aluminum box |
20161020 |
LBT |
MB, JB |
Removed BCU board #00069 and installed BCU board #00048 taken from BcuNumber2 |
20161016 |
LBT |
MB |
Removed from LgswRack1, HVC board 0006 and 0119 moved to BcuNumber2 |
20150525 |
LBT |
GR, LB |
Removed from LgswRack1. Ready to be shipped to MicrogateSrl for power supply upgrade |
20140403 |
OAA |
MA, GOX, LB |
Removed from LgswRack2 and back in MicrogateSrl to fix the FLAO Input port |
20201005 |
LBT |
GR |
Removed from SX LgswRack2. Installed in DX LgswRack1 (exchanged with BcuNumber2). IP address changed to 192.168.31.141 using VirtualBox. |
20210622 |
LBT |
GR |
Sent to MicrogateSrl for repair. |
20140417 |
OAA |
MB |
shipped to LBT |
20161117 |
MPE |
JZ |
Shipped to MIC for repairing of BCU board and DSP |
20170417 |
MIC |
MA, HG |
Shipped to MPE and LBT |
20170919 |
LBT |
GR |
Stored in ArgosCabinet0 |
20220305 |
LBT |
GR |
Taken to the observatory. |
20141103 |
LBT |
GOX |
Update of the BCU NIOS to BCUNios_5_09_0046 + use of two new ldr file (BCU 6_10, DSP_2_05) |