Summary of AO loop disturbances for the ArgosSystem

Using the ARGOS CalUnit the number of reflections on the secondary is one.

Useful link: HowToConvertDisturbanceInNewModalBasis.

KL_v22, DX side

Disturbance Tag Seeing ["] r0@500nm [m] L0 [m]
20180221_160000 1.6 0.0632 40.0
20180221_120000 1.2 0.084 40.0
20180221_080000 0.8 0.1258 40.0
20180221_052000 0.52 0.1935 40.0
20180221_035000 0.35 0.2889 40.0

KL_v16, DX side

Disturbance Tag Seeing ["]Sorted descending r0@500nm [m] L0 [m]
20150407_160000 1.6 0.0632 40.0
20150407_120000 1.2 0.084 40.0
20150407_080000 0.8 0.1258 40.0
20150407_052000 0.52 0.1935 40.0
20150407_035000 0.35 0.2889 40.0

KL_v20, SX side

Disturbance Tag Seeing ["] r0@500nm [m] L0 [m]
20180224_150000 1.5 0.067 40.0
20180224_120000 1.2 0.084 40.0
20180224_100000 1.0 0.101 40.0
20180224_080000 0.8 0.126 40.0
20180224_060000 0.6 0.168 40.0
20180224_040000 0.4 0.252 40.0

KL_v18, SX side

Disturbance Tag Seeing ["] r0@500nm [m] L0 [m]
20151211_150000 1.5 0.067 40.0
20151211_120000 1.2 0.084 40.0
20151211_100000 1.0 0.101 40.0
20151211_080000 0.8 0.126 40.0
20151211_060000 0.6 0.168 40.0
20151211_040000 0.4 0.252 40.0